Control valve Anti-Hammer

Pressure sustaining and relief valve type E2116-00

Picture1

Choice of the valve
The pressure sustaining/relief valve E2116-00 is controlled by a normally closed diaphragm actuated, two way, spring loaded, adjustable pressure discharging control valve (rep 1), set to maintain a minimum and constant pressure at valve inlet. When upstream pressure increases to the sustaining/relief set point, the control pilot (rep1) throttles towards open, increasing flow through the pilot circuit; pressure is decreased in the main valve control chamber, inducing the main valve to modulate towards open an appropriate amount, relieving excess upstream pressure through the main valve to its outlet. The opening speed can be adjusted by independent flow regulator “OPENING SPEED = OS” located in lockable central control “TUP – 93” rep7).

As the upstream pressure decreases to the sustaining/relief set point, the control pilot (rep1) throttles towards closed, restricting the flow through the pilot circuit. Pressure is increased in the main valve control chamber, inducing the main valve to modulate towards closed an appropriate amount, maintaining the desired upstream pressure. The closing speed can be adjusted by the independent flow regulator “CLOSING SPEED = CS” located in the lockable central control “TUP-93”. If upstream pressure is dropping below the sustaining/relief set point and is remaining below the set point, the main valve is closing drop-tight.

PN10-16
DN(mm) A(mm) B(mm) K(mm) D(mm) E(mm)
50 230 148 246 165 85
60 290 148 246 185 95
65 290 148 246 185 95
80 310 148 246 200 100
100 350 206 272 220 110
125 400 267 330 250 125
150 480 267 330 285 145
200 600 356 402 340 170
250 730 445 569 400 200
300 850 597 649 455 230
350 980 597 649 520 255
400 1100 750 786 565 285
500 1250 842 840 670 335
600 1450 905 956 780 390